Loading...
R-23-26VILLAGE OF DEERFIELD STATE OF ILLINOIS ) COUNTIES OF LAKE AND COOK ) SS VILLAGE OF DEERFIELD ) Image# 063212590030 Type: AGR Recorded: 06/21/2023 at 04:25:27 PM Receipt#: 2023-00026353 Page i of 30 Fees: $50.00 IL Rental Housing Fund: $0.00 Lake County IL Anthony Vega Lake County Clerk • : II11:Y The undersigned hereby certifies that he is the duly appointed Deputy Village Clerk of the Village of Deerfield, Lake and Cook Counties, Illinois, and that the attached is a true and accurate copy of Business Fagade Rebate Agreement between the Village of Deerfield and Kirby Limited Partnership dated June 12, 2023. Dated this June 14, 2023. GOF D . FiQ . O , �Ir � • SEAL SEAL Lai %ft DANIEL VAN DUSEN Deputy Village Clerk Prepared by and after recording return to Daniel Van Dusen Village of Deerfield 850 Waukegan Road Deerfield, IL 60015 850 WAUKEGAN ROAD DEERFIELD, ILLINOIS 60015 TELEPHONE 847.945.5000 FAX 847.945.0214 VILLAGE OF DEERFIELD RESOLUTION NO. 2023- R-23-26 APPROVING AN APPLICATION BY KIRBY LIMITED PARTNERSHIP FOR PARTICIPATION IN THE BUSINESS FACADE REBATE PROGRAM (728 WAUKEGAN ROAD) WHEREAS, the Village of Deerfield ("Village') is a home rule municipality in accordance with Article VII, Section 6 of the Constitution of the State of Illinois of 1970; and WHEREAS, pursuant to Article 17 of Chapter 7 of ""The Municipal Code of the Village of Deerfield, Illinois, 1975", as amended ("Village Code'), the Village has created a business facade rebate program ("Program') for owners of businesses located in the C-1 Village Center District or C-2 Outlying Commercial District of the Village that meet certain criteria to obtain financial assistance for eligible site improvements and renovations of building facades; and WHEREAS, a goal of the Program is to financially assist the owners of commercial buildings aged 15 years or older in the Village with the cost of improving, remodeling and renovating exterior building facades and sites to encourage private investment in the Village; enhance the overall tax base of local taxing districts by the further development and improvement of eligible private building facades and sites; improve the safety and accessibility of the Village's commercial districts; and create a greater sense of community, improve pedestrian walkability, and improve the overall aesthetics of the Village's commercial districts; and WHEREAS, to be eligible for participation in the Program, the owners of commercial buildings must make an investment of not less than $10,000 for eligible fagade and site improvements; and WHEREAS, the Program provides that the Village will reimburse approved commercial owners for 50 percent of the costs for eligible improvements not to exceed $50,0000 for building improvements and not to exceed $50,0000 for property site improvements; and WHEREAS, Kirby Limited Partnership ("Owner's owns the Property located at 728 Waukegan Road; and WHEREAS, the Owner desires to make building fagade and site improvements on the Property, and has submitted an application to participate in the Program ("Application'); and WHEREAS, the Mayor and Board of Trustees have determined that granting Owner's Application will serve and be in the best interest of the Village and its residents; NOW, THEREFORE, BE IT RESOLVED BY THE VILLAGE BOARD OF DEERFIELD, LAKE AND COOK COUNTIES, ILLINOIS, as follows: {00128728.1 } SECTION 1: RECITALS. The Village Board hereby adopts the foregoing recitals as its findings, as if fully set forth herein. SECTION 2: APPROVAL OF REBATE. Pursuant to the Village's home rule authority, the Application by Owner for participation in the Program is hereby granted and the Village is hereby authorized to issue a rebate for eligible building and site improvements on the Property in amounts not to exceed: Building Improvements: $50,000 Site Improvements: $50,000 SECTION 3: APPROVAL OF BUSINESS FACADE REBATE AGREEMENT. The Business Fagade Grant Agreement ("Agreement') by and between the Village and the Owner is hereby approved in substantially the form attached to this Resolution as Exhibit A, and in a final form to be approved by the Village Attorney. SECTION 3: EXECUTION OF DEVELOPMENT AGREEMENT. The Village Mayor and the Village Clerk are hereby authorized and directed to execute and attest, on behalf of the Village, the Agreement upon receipt by the Village Clerk of at least one original copy of the Agreement executed by the Owner. events: SECTION 4: EFFECTIVE DATE. A. This Resolution will be effective only upon the occurrence of all of the following Passage by the Village Board by a majority vote in the manner required by law; and 2. Execution by the Owner of the Agreement. B. In the event that the Applicant does not deliver fully executed copies of the Agreement within 30 days after the date of final passage of this Resolution by the Village Board, the Mayor and Board of Trustees will have the right, in their sole discretion, to declare this Ordinance null and void and of no force or effect. [SIGNATURE PAGE FOLLOWS] {00128728.11 AYES: Benton, Berg, Jacoby, Metts-Childers, Oppenheim, Seiden NAYS: None ABSTAIN: None ABSENT: None PASSED: June 5, 2023 APPROVED: June 5, 2023 RESOLUTION NO: R-23-26 Daniel C. Shapiro, Mayor ATTEST: Kent S. Street, Village Clerk 100128728.11 EXHIBIT A AGREEMENT 100128728.11 THIS DOCUMENT PREPARED BY AND AFTER RECORDING RETURN TO: Benjamin Schuster Elrod Friedman LLP 325 N. LaSalle Street Suite 450 Chicago, IL 60654 Above Space For Recorder's Use Only BUSINESS FACADE REBATE AGREEMENT This Agreement is dated this Itclay of Ln2 , 2023 by and between the VILLAGE OF DEERFIELD, an Illinois home rule municipal corporation, located at 850 Waukegan Road, Deerfield, IL 60015 ("Village'), and KIRBY LIMITED PARTNERSHIP ("Owner'). The Village and Owner are jointly referred to herein as the "Parties." RECITALS: WHEREAS, pursuant to Article 17 of Chapter 7 of "'The Municipal Code of the Village of Deerfield, Illinois, 1975", as amended ("Village Code', the Village has created a business facade rebate program (`Program"j for owners of businesses located in the C-1 Village Center District or C-2 Outlying Commercial District of the Village to provide financial assistance for eligible site improvements and renovations of building facades; and WHEREAS, a goal of the Program is to financially assist the owners of commercial buildings aged 15 years or older in the Village with the cost of improving, remodeling and renovating exterior building facades and sites to encourage private investment in the Village; enhance the overall tax base of local taxing districts by the further development and improvement of eligible private building facades and sites; improve the safety and accessibility of the Village's commercial districts; and create a greater sense of community, improve pedestrian walkability, and improve the overall aesthetics of the Village's commercial districts; and WHEREAS, to be eligible for participation in the Program, the owners of commercial buildings must make an investment of not less than $10,000 for eligible fagade and site improvements; and WHEREAS, the Program provides that the Village will reimburse approved commercial owners for 50 percent of the costs for eligible improvements not to exceed $50,0000 for building improvements and not to exceed $50,0000 for property site improvements; and WHEREAS, the Owner owns the property commonly known as 728 Waukegan Road in {00128727.1} the Village, and legally described in Exhibit A attached hereto and incorporated herein ("Property's; and WHEREAS, the Owner has submitted an application to the Village to participate in the Program, and the Village has approved the application pursuant to Resolution R-23-26 ("Approval'; and WHEREAS, the Approval is conditioned upon the Owner entering into this Agreement and abiding by the terms of this Agreement; NOW THEREFORE, in consideration of the premises set forth above, and the mutual agreement hereinafter set forth below, it is hereby agreed by and between the Parties as follows: SECTION 1. INCORPORATION OF RECITALS. The foregoing recitals are incorporated into, and made part of, this Agreement as though they were fully set forth in this Section 1. SECTION 2. BUILDING AND SITE IMPROVEMENTS. The building improvements set forth in Exhibit B ("Building Improvements'), attached hereto and incorporated herein, and Site Improvements set forth in Exhibit B ("Site Improvements') (the Building Improvements and Site Improvements are, collectively, the "Approved Improvements') are eligible for a rebate under the Program pursuant to the terms of this Agreement. Any building improvements or site improvements to the Property not set forth in Exhibit B are not eligible for any rebate from the Village. SECTION 3. PROOF OF OWNERSHIP. Owner represents and certifies that Owner is the legal title holder of the Property and is duly authorized to enter into this Agreement. Before any Rebate shall be paid, Owner must submit satisfactory proof to the Village of Owner's legal or beneficial ownership of the Property, which proof must include: A. A current title policy or title commitment showing Owner as the current title owner of record, or a copy of the recorded deed that vests Owner with good and merchantable title to the Property; and B. If title to the Property is held in trust, Owner shall also submit: (i) a certified copy of the Trust Agreement, (ii) certification as to the current beneficiary under such Trust Agreement, and (iii) a letter of direction authorizing execution of this Agreement. SECTION 4. OWNER'S REPRESENTATIONS. Village has relied upon all information provided by the Owner and upon all representations, exhibits, data, and other supporting materials submitted with and in support of Owner's application for participation in the Program. Any misinformation or withholding of material information incident thereto shall, at the option of the Village, give rise to the Village's right to terminate this Agreement and require Owner to immediately repay to the Village any amounts paid by the Village to Owner pursuant to this Agreement. This repayment obligation shall survive termination of this Agreement. SECTION 5. ELIGIBILITY FOR REBATE. Upon the completion of all Approved Improvements in accordance with this Agreement and all applicable requirements of law (including all applicable building codes) and inspection of the Approved Improvements by the Village, Owner shall submit to the Village Manager the following documents: 2 {00128727.1} A. All contracts and/or invoices showing the final amounts charged for all of the Approved Improvements; B. All receipts or other forms of proof of payment showing that Owner has paid for the Approved Improvements in full; and C. Contractors' final certificates and waivers of lien for all Approved Improvements. Upon submission of the above -listed documents, in a form satisfactory to the Village Manager, the Village shall issue a rebate to the Owner within 30 days in an amount not to exceed the lesser amount of: (i) 50 percent of the final actual cost for the Building Improvements and Site Improvements itemized in Exhibit B; and (ii) the following maximum project rebate amounts: Building Improvements: $50,000 Site Improvements: $50,000 SECTION 6. LICENSES AND PERMITS. Owner acknowledges and agrees that: (i) Owner is responsible for securing all necessary licenses and permits for the proper and complete construction and installation of the Approved Improvements; and (ii) nothing in this Agreement obligates the Village to issue any building permits or approvals to Owner or Owner's contractors related to the Property or the Approved Improvements. SECTION 7. Timely Completion of Approved Improvements. The Approved Improvements must be properly and completely constructed and installed within 150 days after the adoption of the Approval for Owner to obtain the Rebate ("Deadline'l. In the event that the Approved Improvements are not properly and completely constructed and installed by the Deadline, the Village shall have no obligation to issue the Rebate. SECTION & REPAIR OF DAMAGE. Owner shall repair any damage to Village property, including any rights -of -way, that may be caused by, or occur in connection with, the installation or maintenance of the Approved Improvements. SECTION 9. MAINTENANCE OF APPROVED IMPROVEMENTS. Owner acknowledges and agrees that: (i) it shall maintain all Approved Improvements in a clean and first-rate manner and free from defects for a period of no less than five years from the date of the receipt of the Rebate; and (ii) the Village shall have no obligation to provide any maintenance on the Approved Improvements. SECTION 10. NO ALTERATION OR REMOVAL OF APPROVED IMPROVEMENTS. Owner acknowledges and agrees that, for a period of five years following the receipt of the Rebate, Owner shall not cause or permit the alteration or removal of any of the Approved Improvements without the prior written permission of the Village, which permission the Village may withhold in its sole and absolute discretion. Notwithstanding anything in this Section to the contrary, Owner may alter or remove the Approved Improvements in the event of an emergency causing an immediate safety risk, provided that Owner repairs the Approved Improvements to their condition prior to the emergency. SECTION 11. NOT ELIGIBLE FOR OTHER VILLAGE GRANTS. Owner may not apply to the Village, and the Village shall have no obligation to provide, any other grants or rebates related to (i) the Approved Improvements or (ii) the fagade of the building or for Site Improvements 3 (00128727.1) on the Property for a period of five years from the date of the Approval except as provided in this Agreement. SECTION 12. SALE OF SUBJECT PROPERTY: GRANT OF LIEN. If Owner sells, transfers or conveys all or part of the Property, or any interest in the Property, within five years after receipt of the Rebate, Owner shall at the time of such sale, transfer, or conveyance, reimburse the Village for all or a portion of the Rebate based on the following schedule: YEAR OF SALE AFTER PAYMENT OF REBATE PERCENTAGE OF REBATE OWNER OWES THE VILLAGE Within 1 year 100% Between 1 and 2 years 80% Between 2 and 3 years 60% ' Between 3 and 4 years Between 4 and 5 years 40% 20% In consideration of the Village's Rebate to Owner, Owner expressly grants to the Village a lien upon the Property if Owner fails to reimburse the Village for that portion of the Rebate due to the Village under this Section at the time of any sale, transfer or conveyance of the Property, including Village's reasonable attorneys' fees in enforcing its rights under this Section. SECTION 13. TERMINATION. This Agreement may be terminated at the Village's option by written notice to Owner upon the breach by Owner of any terms of this Agreement or if any statement or representation made by Owner to the Village in applying for eligibility in the Program or to obtain the Rebate shall prove untrue in any material respect, or if the Owner shall have withheld any material information incident thereto. In the event that the Village terminates this Agreement pursuant to this Section, Owner shall immediately repay to the Village any amounts paid by the Village to Owner pursuant to this Agreement. This repayment obligation shall survive termination of this Agreement. SECTION 14. INDEMNIFICATION. Owner shall, without regard to the availability or unavailability of any insurance, either of the Village or Owner, indemnify, save harmless, and defend the Village, and its officials, employees, agents, and attorneys against any and all lawsuits, claims, demands, damages, liabilities, losses, and expenses, including attorneys' fees and administrative expenses, to the extent that arise, or may be alleged to have arisen, out of, the design or installation of the Approved Improvements or any failure to meet the representations, certifications, and obligations of this Agreement, whether or not due or claimed to be due in whole or in part to the active, passive, or concurrent negligence or fault of Owner, except to the extent caused by the sole negligence of the Village. This Section shall survive termination of this Agreement. SECTION 15. GENERAL TERMS. A. Village Not a Joint Venturer. The Village shall not, by executing this Agreement or taking any action pursuant hereto or contemplated hereby, be deemed to be a partner or joint venturer with Owner, Owner's contractors or any other parties. B. Compliance with Requirements of Law. Owner shall give all notices, pay all fees and taxes, and take all other action that may be necessary to accept the Rebate and ensure that the Approved Improvements are constructed, installed, and maintained in accordance with and 4 {00128727.1} with all applicable statutes, ordinances, rules, and regulations. C. Bindinc; Effect. The terms of this Agreement shall bind and inure to the benefit of the Parties hereto and their agents, successors, and assigns. D. Recording of Agreement. The Village may record with this agreement with in the office of the Lake County Recorder of Deeds or the Recording Division of the Cook County Clerk, whichever may be applicable based on the location of the Property. E. Waiver. No waiver of any provision of this Agreement shall be deemed to or constitute a waiver of any other provision of this Agreement, nor shall any such waiver be deemed to or constitute a continuing waiver unless otherwise expressly provided in this Agreement. F. Rights Cumulative. Unless expressly provided to the contrary in this Agreement, each and every one of the rights, remedies, and benefits provided by this Agreement shall be cumulative and shall not be exclusive of any other such rights, remedies, and benefits allowed by iaw. G. Notice. Any notice or communication required or permitted to be given under this Agreement shall be in writing and shall be delivered (i) personally, (ii) by a reputable overnight courier, (iii) by certified mail, return receipt requested, and deposited in the U.S. Mail, postage prepaid, or (iv) by electronic internet mail ("e-mail'). E-mail notices shall be deemed valid and received by the addressee thereof when delivered by e-mail and (a) opened by the recipient on a business day at the address set forth below, and (b) followed by delivery of actual notice in the manner described in either (i), (ii) or (iii) above within three business days thereafter at the appropriate address set forth below. Unless otherwise expressly provided in this Agreement, notices shall be deemed received upon the earlier of (a) actual receipt; (b) one business day after deposit with an overnight courier as evidenced by a receipt of deposit; or (c) three business days following deposit in the U.S. mail, as evidenced by a return receipt. By notice complying with the requirements of this Subsection, each Party shall have the right to change the address or the addressee, or both, for all future notices and communications to such party, but no notice of a change of addressee or address shall be effective until actually received. Notices and communications to the Village shall be addressed to, and delivered at, the following address: Village of Deerfield 850 Waukegan Road Deerfield, IL 60015 Attention: Andrew Lichterman E-mail: aiichterman@deerfield.il.us Notices and communications to Owner shall be addressed to, and delivered at, the following address: Kirby Limited Partnership 740 Waukegan Road — Suite 300 Deerfield, Illinois 60015 5 (00128727.1) Chris Siavelis Email: csiavelis@crmproperties.com H. Third Party Beneficiary. No claim as a third party beneficiary under this Agreement by any person, firm, or corporation other than Owner shall be made or be valid against the Village. I. Provisions Severable. If any term, covenant, condition, or provision of this Agreement is held by a court of competent jurisdiction to be invalid, void, or unenforceable, the remainder of the provisions shall remain in full force and effect and shall in no way be affected, impaired or invalidated. Time. Time is of the essence in the performance of this Agreement. K. Governing Laws. This Agreement shall be interpreted according to the internal laws, but not the conflict of laws rules, of the State of Illinois. L Joint and Several Liability. In the event that that more than one person or party is executing this Agreement as Owner, those persons or parties shall be jointly and severally liable for all of Owner's obligations and liabilities under this Agreement. M. Entire Agreement. This Agreement constitutes the entire agreement between the parties and supersedes any and all previous or contemporaneous oral or written agreements and negotiations between the Village and Owner with respect to the Rebate. IN WITNESS WHEREOF, the Parties have hereunto set their hands on the date first above written. ATTEST: 7tii�7tf Village CI rk ATTEST: B r Its: S \/ 6 {00128727.1 } VILLAGE OF DEERFIELD, an Illinois home rule munici I corporation By: Daniel C, Shapiro Its: Mayor KII By Its ACKNOWLEDGMENTS STATE OF ILLINOIS ) ) SS. COUNTY OF LAKE ) This instrument was acknowledged before me on v► , 2021, by Daiie\ C. S"#;ra , the Mayor of the VILLAGE OF DEERFIELD, an Illinois municipal corporation, and by ft► kS. S -ke+ , the Village Clerk of said municipal corporation. Given under my hand and official seal this QJ - day of the _ , 2023. Notary Pub lic=�m.,�.:;.. OFFICIAL SEAL My Commission expires:. DANIEL VAN DUSEN NOTARY PUBLIC, STATE OF ILLINOIS SEAL MY COMMISSION EXPIRES:11102/2025 �-�-� STATE OF M-Q/J�, ) SS. COUNTY OF LAKE ) This instru ent was acknowl dged before me on Q Un1E / of , 202J, by CHJ9P .GS HCie _and Given under my hand and official seal this %a lay of TuN E 202 3. Notary Public My Commission expires: S OFFICIAL SEAL KATHLEEN A TIERNEY [MY OTARY PUBLIC - STATE OF ILLINGS COMMISSION EXPIRES:10/04/24--------------------- 7 {00128727.1) EXHIBIT A LEGAL DESCRIPTION OF THE PROPERTY PARCEL 1: LOTS 1 AND 2 IN THE SHOPS AT DEERFIELD SQUARE, BEING A RESUBDIVISION OF PART OF THE NORTHEAST 114 OF SECTION 32 AND THE NORTHWEST 1/4 OF SECTION 33, TOWNSHIP 43 NORTH, RANGE 12 EAST OF THE THIRD PRINCIPAL MERIDIAN, ACCORDING TO THE PLAT THEREOF RECORDED AUGUST 15, 2001 AS DOCUMENT NUMBER 4746622, LAKE COUNTY, ILLINOIS PARCEL 2: EASEMENT FOR VEHICULAR INGRESS/EGRESS AND ACCESS FROM AND TO OSTERMAN AVENUE FOR THE BENEFIT OF LOT 1 IN PARCEL 1 AS DEPICTED OVER THAT PART OF LOT 3 IN THE SHOPS OF DEERFIELD SQUARE, A RESUBDIVISION OF PART OF THE NORTHEAST 114 OF SECTION 32 AND THE NORTHWEST 1/4 OF SECTION 33, TOWNSHIP 43 NORTH, RANGE 12 EAST OF THE THIRD PRINCIPAL MERIDIAN, ACCORDING TO THE PLAT THEREOF RECORDED AUGUST 15, 2001 AS DOCUMENT NUMBER 4746622, IN LAKE COUNTY. ILLINOIS. AS GRANTED BY INSTRUMENT RECORDED APRIL 3, 2001 AS DOCUMENT 4667858. P.I.N.s 16-32-207-002, 16-33-101-024, 16-33-101-025 Commonly known as: 720-780 Waukegan Road; 711-833 Deerfield Road; 700 and 750 Osterman Avenue; and 710-766 Robert York Road, Deerfield, Illinois ADDRESS: 728 Waukegan Road, Deerfield, IL 60015 EXHIBIT B Exhibits Describing Building Improvements and Site Improvements Hill AA 111�� , 11111 1 HIM ure A a h!mA 728 COFFEE thieis F _ 5 H, Tech EXISTING BUILDING EXTERIOR PHOTOS Stantec 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL K ,FE�riF .-,;RO, L. D. OFFICE + RETAIL EXISTING BUILDING EXTERIOR FRONT VIEW 9' -4" L -t - Stantec 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL �KDPERTIES GROUP i OFFICE + RETAIL PROPOSED EXTERIOR FRONT VIEW -�� `r.t - r.� A Orr AS Stantec 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL TES �:R 1 r OFFICE + RETAIL m I III I r��■ �r 36CPFFEE athleisure 44" F r�- - � s '1 Hill F A S H i 36 Tech Mare 32'f dQ QQ 1111 111 1 llllii� � i 111�1 �111 - � � Hill111- 728 COFFEE F A S H 10 N TeCh stofe i • ..'"`' . ti� �! w - •y - - PROPOSED OFFICE ENTRANCE r� 13- in m LEGEND 1. BRICK - RED 2. BRICK — GRAY 3. METAL PANEL — DARK GRAY -- 4. STONE CAP — LIGHT GRAY 5. CANVAS AWNINGS - BLACK 6. RETAIL SIGNAGE - WHITE 7. STOREFRONT GLAZING 8. STONE BASE — LIGHT GRAY 9. GLASS BALCONY RAILING 10. STONE LINTEL — LIGHT GRAY 11. WOOD BOARD CEILING 12. KNEE WALL — RED BRICK 13. REVOLVING DOOR 5 - _ ta s _ Stantec r 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL PRE r L 11 EXISTING REAR FACADE 4 Stantec 03.08.2022 1 728 WAUKEGAN RD DEERFIELD, IL IT OFFICE + RETAIL PROPOSED REAR FACADE LEGEND 1. EXISTING BRICK - TO REMAIN 2. EXISTING STUCCO - PAINT LIGHT GRAY 3. EXISTING STUCCO CAP W/ METAL COPING - PAINT LIGHT GRAY 4. EXISTING STUCCO CAP W/ METAL COPING - PAINT DARK GRAY 5. EXISTING STONE - TO REMAIN 6. NEW STOREFRONT GLAZING 7. EXISTING STONE BASE - TO REMAIN 8. NEW PAINTED METAL DOOR 9. EXISTING PAINTED METAL DOOR - PAINT DARK GRAY 10. EXISTING TRASH ENCLOSURE - TO REMAIN 4 Stantec I 03.08.2022 728 WAUKEGAN RD aw DEERFIELD, IL PROPERTIES GROUP. LT !- OFFICE + RETAIL PROPOSED PLAN DIAGRAM GROUND FLOOR 25'-0" RETAIL BAY 1 2,207 SF x II ayJ O O ,a.a• { UP I N I 1 I WEST STAIR 25'-0" 50'-0" 25'-0" 25'-0" 15'-0" 10'-0" 10'-0" 19'-0" 19'-01, 10'-0" 10'-0" � - 1 I I OFFICE RETAIL RETAIL RETAIL LOBBY BAY 2 BAYS 3& 4 i BAY 5 ESE 2,511 SF 5,037 SF 3,243 SF I 1 I I I I 1 I i RETAIL 1 12,998 SF 1 49'-0• 1 1 1 i I i rp, rR-T71 R=T7 111 x l II x IIII x It Lie=1a Lie=yJ 1 L�=)o 1 I I SvC i I I I I i 150'-0" SVC, COR,,-- N SCALE 1/16"= 1'-0" (JoStantec 1 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL �ROFIERTIES GROAR LT_7. ® o, 8' 16' 32' OFFICE + RETAIL PROPOSED PLAN DIAGRAM SECOND FLOOR - SINGLE TENANT 150'-0" OFFICE: 13,344 usf N SCALE 1/16" = 1'-0" Stantec 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL @RoPERnt4 &R U - ® o' s 16' 32' OFFICE + RETAIL PROPOSED PLAN DIAGRAM SECOND FLOOR - MULTI -TENANT I 150'-0" OFFICE: 13,344 usf N SCALE 1/16" = 1'-0" StanteC 03.082022 728 WAUKEGAN RD DEERFIELD, IL 3ioPERriEs ::� U: Lr•�a_ OFFICE +RETAIL ® 0' 8' 16' 32' PROPOSED OFFICE LOBBY Stantec 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL Y PROPERTiESGROUP. u a OFFICE +RETAIL EXISTING SITE PLAN r Stantec 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL 7 1 {---� _ ^ ^ — - EXISTING ACCESSIBLE PARKING SPACES TO BE 2 spaces REMOVED AND RELOCATED 930 sf + _ 3spaces 2 saces p 800 sf ± - 4 .S'+ - EXISTING PLANTED ! 910 sf ± — 40 ± AREA TO BE REMOVED 250 sf + . f — 1000 sf I4'± ---- ---- -- —.��_- - r --- —(31 EXiSTING SPACES TO IS REMLVEL' 2 STORY BARNES & NOBLE r RR."PER ClES G,'R' P U _-- TOTAL SPACES: 31 TOTAL ACCESSIBLE: 7 TOTAL STANDARD: 24 SF OF PARKING REMOVED: 2,640 sf + SF OF PLANTING REMOVED: 1,250 sf + TOTAL SF OF PAVING ADDED. 3,890 sf + ® SCALE 1 " = 30' 0 15 30 60 OFFICE +RETAIL PROPOSED SITE PLAN I us CURB LINE ADJUSTED TO ADD J2) ACCESSIBLE SPACES WITH SHARED AISLE 343 ---------- L r(T-7 7 L 16 spates:, 1.5'C&G ' 1 PLANTER WALL 5' PLANTER KNEE WALL / PLANTER ri 20'+ OUTDOOR ■ 2000sf SEATING AREA OUTDOOR SEATING ------------- F kly Stantec 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL PRDPERTIESGPOUR 11 L—(3) STANDARD SPACES CONVERTED TO (2) ACCESSIBLE SPACES WITH SHARED AISLE FILL IN PLANTED AREA WITH PAVERS TOTAL SPACES: 25 TOTAL ACCESSIBLE: 7 TOTAL STANDARD: 18 LOSS OF (6) TOTAL SPACES ALL ACCESSIBLE SPACES MAINTAINED RELOCATED N SCALE r = 30' OFFICE + RETAIL 0 15 30 60 PROPOSED PLANTER ENLARGEMENT Feather Reed Grass Height: 3.00 to 5.00 feet Spread: 1.50 to 2.50 feet Big Blue Lilyturf Height: 1.00 to 2.00 feet Spread: 1.00 to 2.00 feet Little Lime Hydrangea Height: 3.00 to 5.00 feet Spread: 3.00 to 5.00 feet Nepeta Height: 1.00 to 1.50 feet Spread: 1.00 to 2.00 feet { Annuals Height: 0.50 to 1.50 feet Spread: 0.50 to 1.00 feet PLANT SCHEDULE SCIENTIFIC NAME COMMON NAME CODE QUANTITY SIZE AT PLANTING SPACING Calamagrostis x Feather Reed Grass CA 25 12" SPR., 18" HT. 2' OC acutiflora 'Karl Foerster' Liriope muscari 'Big Blue' Big Blue Lilyturf LM 9 12" SPR., 12" HT. 12" OC Hydrangea paniculata Little Lime@ Hardy HP 12 24" SPR., 24" HT. 3' OC 'Jane' Hydrangea Nepeta X faassenii 'Select Nepeta NF 58 12" SPR., 12" HT. 18" OC Blue' Annuals Annuals AN 66 SF 6" SPR., 6" HT. 6" OC (18 SF) AN (3) HP NF (3) HP (3) HP (9) LM (17) (17) NF — (12) NF (N (5) CAA {5) CA (12) NF (3) CA (24 SF)AN Z//- i 51 (3) HP (3) CA (24 SF) AN CURB 8 GUTTER MASONRY KNEE WALL Stantec 03.08.2022 728 WAUKEGAN RD DEERFIELD, IL FR TIES, RvJR LTD- ® SCALE 1 10' "5 10 20 OFFICE + RETAIL 0.2 0.5 1.1 0.2 0.5 1.1 1.7 0.9 0.4 0.1 1.7 0.9 0.3 0.1 0.1 0.3 0.8 1.4 1.9 2.1 1.9 1.4 1.0 0.9 1.2 1.5 1.8 1.9 1.9 1.9.. 1.9 1.8 1.6 1.2 0.8 0.7 1.0 1.5 2.0 2.1 1.8 1.2 0.6 0.2 0.1 0.0 0.2 0.4 0.7 1.0 1.1 1.0 0.7 0.5 0.4 0.5 0.7 0.8 0.8 0.8 0.8 0.8 0.8 0.7 0.5 0.4 0.3 0.5 0.8 1.0 1.1 0.9 0.6 0.3 0.1 0.0 EXTERIOR ENTRY WALKWAYS Lighting Layout and Calculations Luminaire Schedule Symbol Qty Label I Lum. Lumens LLF I Description + 8 1 CX1 2082 0.450 P4RDL20635CLZ10U 'LLF MODIFIED FROM 2000 LUMEN TO 1000 LUMEN A Calculation Summary M Label CalcType I Units I Avg Max Min Avg/Min Max/Min GridZ 1 T SIDEWALK Illuminance Fc 1.54 3.8 0.0 N.A.N.A. 0 Fay . Q This document contains confidential and proprietary information to Connexion. This calculation information is not a technical submission or technical report and is provided for informational purposes only. It is the obligation of the end -user to consult with a professional engineering firm or professional design firm to determine whether this calculation information meets the applicable project requirements for lighting system performance, health and human safety, suitability, and effectiveness for use in a particular application. Field verification is recommended when calculations are based on end -user or customer -provided information. End -user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual field performance to differ from the calculated photometric performance represented in this lighting design. In no event will Connexion be responsible for any loss resulting from any use of this calculation information. n go W 7 • U J Q LLI U) w + a W O U z LL Q LL O U z w w Y O 7 z 0 00 Page 1 of 1 LyteProfile downlights and wall washers provide a perfect balance of I unctionality With glare control. The robust and versatile UniFrame frame -in kit makes changes and updates easy to manage and install. Ideal for use in a variety of applications including open office, institutional, healthcare, and retail. Complete unit = Fixture + Light Engine/Trim + Optional Accessories Frame example: 4RN Series Aperture Installation Options a a ❑ � 4 Uniframe 4-inch Non -IC R Round N New construction Non -IC) — Universal 120/277/347V' 3 347V (for non-0-10v configurations) LC Chicago Plenum RADIO Integral Interact Pro RF sensor (120/277/347V) EM6 Emergency, 6W (enables wireless connected lighting control)' Self-Test/Self-Diagnostic 2 R Remodeler (Non -IC) — Universal 120/277/347V' 3 347V (for non-Z10 configurations) A AirSeal(Ic) — Universal 120/277/347V' Light Engine/Trim example: P4RDL20835CDZ10U SeriesStyleI Sty Lumen CRICRI/� Reflector I Flange Dim ] Voltage Options P4R LyteProfile DL Downlight 05 5001m 827 80CRI / 2700K CL Specular clear — White (matte) Z10 0-10V1% U 120/277V 4-inch LW Lensed (0-10Vonly) 830 80CRI / 3000K CC Comfort clear B Black (matte) 3 347V5,6 Round Wall Wash 10 10001m 835 80CRI / 3500K CD Comfort clear P Polished (o-lovonly) L Lutron LDEI U 120/277/ Ecosystem 347V (fade -to -black) downlight SL Shower light° (non-conductive lens) 15 15001m 20 20001m 25 25001m 840 80CRI / 4000K 850 80CRI / 5000K diffuse (matches aperture) WH White (matte) BK Black (matte) — White (matte) B Black (matte) WHAMF White — White (gloss) (gloss antimicrobial) Accessories — None R Retrofit (not compatible with IEM6) IEM6 Trim mounted EM test switch' SBA Interact Ready System Bridge Accessory with integral occupancy and daylight sensor (compatible with all 0-10V options, see SBA spec sheet)? CAEM6 Field installable Bodine BSL6 6W battery pack with self-test/self-diagnostic for use with new construction frames, 120-277V 7920 4" sloped ceiling adapter (refer to SCA spec sheet for slope options) AMS ActiLume multi -sensor (optional accessory for PoE configurations) 1 Universal 120-347V is for 0-10v (Z10) dimming configurations only. For 347V non-Z10 dimming, order 347V (3) frame with (U) light engine/trim- 2. Emergency (EM6) frame is compatible with reflector mounted test switch when light engine is ordered with IEM6 option code (not compatible with 347V or Power over Ethernet configurations). 3. Interact Pro (RADIO) requires above ceiling access, 4. Shower light (SL) in only available with White (WH) reflector finish. 5. Specify standard UNV frame for use with 347V light engines 6. The 347V light engine voltage option is only available with Z10 dimming option. For other dimming protocols order UNV (U) light engine and 347V (3) frame. 7. Requires IRT9015 IR remote and Interact Pro App for commissioning. 8. IEM6 option available on DL style only, int ermt Ic @Ds RoHS INSULATION 07MM E 1. LyteProfile-4in-P4R 12/21 page 1 of 6 CONTACT LOCATION LISTED ®a P4R LyteProfile 4" Round Downlight & Lensed Wall Wash Features Optics Provides a 60' cutoff (physical and reflected) Wide beam distribution for general illumination Spun and anodized reflectors available in specular (clear), semi-specular (comfort clear and diffuse finishes. Also available in white and black painted finishes. Quality of light Consult factory for RAL finishes Color consistency. 3SDCM 80 CRI minimum Construction (New Construction) Galvanized stamped steal for dry / plaster ceilings. Pre -installed telescoping mounting bars (13"-24") Frame accommodates C- channel, black iron. and 3/4" EMT for mounting distances greater than 24" between joists. Manufactured from 20 gage galvanized steel construction with rolled edge aperture to guide cutting tools for perfect hole cutting_ Max ceiling thickness is 1.5" (38 mm). Including PoE frame 4.88" (124 mm). Patented install Mounting frame Pre -installed mounting bars allow for fast and tool -less install into T-grid & hat channel ceilings Close -cut aperture design eliminates an undesired gap between ceiling material and reflector. Simple plug -and -play connection between frame and light engine from below the ceiling allows for: Easyupgrades Technology changes Repairs and troubleshooting Dimming - Advance 0-10V 1% dimming - Lutron Hi-lume Ecosystem H Series 1% dimming - EldoLED ECOdrive Dali 1% dimming - EldoLED SOLOdrive 0-10V 0.1 % dimming - EldoLED DMX POWERdrive Finishes Light engine Quick connect power pack allow for easy installation and replacement from below ceiling with no need for additional wiring. This allows for: Frame and ceiling installation to be performed while still finalizing details such as lumen packages, CCT and control type. Easy replacement of electronics at end of life with minimal wasted material and labor required. Ease and upgradability of technology. Lumen Maintenance: L80 at 60,000 hours. 347V light engines are 0-10v dimming only and include dedicated 347V driver for use with universal 120/277/347V (U) frames. For 347V and non-0-10v dimming, order (U) light engine and 347V (3) frame (includes step down transformer). Emergency Bodine BSL6 6W battery pack with self -test/ diagnostic functionality. Factory or field mounted to frame. For trim with integral emergency test switch, order light engine with IEM6 option (ex; P4RDL20835CDZ10UIEM6). DL or SL styles only. For remote ceiling mounted test switch, order standard light engine (ex: P4RDL20835CDZ10U), Optional accessory ceiling mounting plate available (CAEM6TSCP) for remote mounted test switch. Refer to Calculite-LyteProfile-EasyLyte Emergency Battery Pack specification sheet for more details. Retrofit Easily updates legacy LyteProfile LED downlights to the latest technology. Includes light engine, trim, and driver mounted on cover plate that mounts to previous generations of LyteProfile LED luminaires. Order with R option code at end of light engine/trim catalog number. Specular clear Comfort clear Comfort clear diffuse Most specular and Semi-specular finish that Slightly diffuse clear therefore most efficient softens the light at the finish, which eliminates finish, delivers maximum source of the reflector iridescence and reduces photometric performance and creates a subtle, the mirror image but can produce a mirror even luminance from effect inherent with a image effect of the the reflector cone, specular finish. interior space. LyteProfile-4in-P4R 12/21 page 2 of 6 Power over Ethernet Powered via Philips PoE lighting controller: complies with FCC rules per Title 47 part 15 (Class A) for EMI / RFI (conducted & radiated). PoE lighting controller accessible from below ceiling. Options and Accessories Sloped ceilings: Compatible with sloped ceiling adapters (see SCA spec sheet). Field Installed Emergency: Refer to Calculite- LyteProfile-EasyLyte Emergency Battery Pack specification sheet for more details. CAEM6: Field install EM6 kit with Bodine BSL6 6W battery pack with self-test/self-diagnostic, mounts to new construction frames. Includes remote ceiling plate for test switch. To mount test switch to trim for new construction frame, order light engine with IEM6 option code (e.g. P4RDL20835CDZ10UIEM6). CAEM6TSCP: Ceiling cover plate for remote mounted EM6 test switch, 1/2" (25mm) hole, 4 3/8" (109mm) x 2 3/4" (69mm) rectangular. Includes two mounting screws. ENERGY STARO exceptions - 5001m configurations - Black finishes - PoE drivers Labels and Listings - cULus listed for wet locations - CCEA (frames with *LC suffix) - ENERGY STAR® certified - RoHS certified Warranty B5 year limited warranty Visit Signify.com/warranties for more information on Signify's standard 5-year limited warranty ❑� rTii•: • on complete luminaire systems. White Brightest aperture when illuminated and provides• the smoothest transition to most ceilings when off (white is only available with a white flange). 4W Black Specular finish that provides the lowest aperture brightness possible and reduces source identification in a ceiling significantly (black is only available with a black flange). P4R LyteProfile 411 Round Downlight & Lensed Wall Wash interact i !ili11ii1ing, grouping, and zoning 3luotooth and ZigBec- enabled Motion sensing and daylight harvesting Integration with 0-10V and phase dimming fi;ctures Code compliance Granular dimming and dwell'time _, ergy reporting and monitoring Scheduling Damanc-'. res; onse y' SMS integration (BACnet) Floor plan'visuaiization IoT sensors `or wellness loi Apps For productivity To be able to design the lighting system correctly for the customer, it is important to know the prime characteristics of the system, its possibilities and limitations. Total number of gateways Total number of devices luminaires with integrated sensors smart TLEDS Total number of ZGP devices (sensors and switches) sensors switches zones and groups f.it"'C+G : 0�-' %coT Unlimited 200 per network 150 150 50 30 50 64 Recommended number of lights 40 (recommended 25) Number of ZGP devices 5 Number of scenes 16 i�re:ar. oAP Ruic.g c.•n. e_tivi.y F.ritige vr:r_ae. wo-eiesa gateway i - +:' Advancnri ` l:aaery w,ry..leps wminaree C-✓ 1^.=01 Pease dimmilg "U ?9w8r?d v,iU^. �nbnrated sensor:r:octde module icy load c0:4crU� module --. - P4R LyteProfile 411 Round Downlight & Lensed Wall Wash Wireless Controls Options Interact Pro scalable sensor (System Bridge Accessory with -CS option): CS is a connected sensor with integral occupancy and daylight sensing and supports wireless mesh connectivity, The sensor works in the Foundation mode (similar to SpaceWise) when configured without a gateway or in an Interact Pro Advanced or Enterprise mode if a compatible gateway is used. Interact Pro includes an App, a portal and a broad portfolio of wireless luminaires, lamps and retrofit kits all working on the same system. Startup is implemented via Interact Pro App (Android or iPhone) & BlueTooth connectivity. The App provides flexibility to choose between a gateway or non gateway mode for setup. Setup with the gateway requires wired internet access to the gateway. It is possible to add a gateway at a later point, Prepare project configuration steps remotely and use IRT9015 remote onsite to identify and group devices together. Compatible with: - UID8451/10 wireless dimmer switch - SWS200 wireless scene switch - Battery powered IP42 presence sensor OCC sensor IA CM WH 10/1 - Battery powered IP42 presence & daylight sensor OCC-DL sensor IA CM IP42 WH - Battery powered IP65 presence sensor OCC sensor IA CM IP65 WH - Battery powered IP65 presence & daylight sensor OCC-DL sensor IA CM IP65 WH For more information on Interact Pro visit! www-interact-ligh ting.co m/ interactp rotcalablesyste m. Wired Controls Options Interact Office Wired (PoE): PoE based IoT connected lighting solution for large enterprises that span across multiple floors, buildings and require multiple gateways. Use Interact Office software and insights to increase building efficiency, achieve building wide integration and optimize space through occupancy analytics. Supports advanced IoT Apps on Personal Control, Space Management, wayfinding, room/ desk reservation and offers open APIs for light control and data exchange. PoE lighting controller is accessible from below. Integral sensor option for occupancy sensing (PIR) and/or daylight harvesting available for additional energy savings. Interact Pro Enterprise (System Bridge Accessory with -SB option): A wireless IoT connected lighting solution for large enterprises that span across multiple floors, buildings and require multiple gateways. View all your projects under one dashboard and easily compare insights from multiple projects in one view. Compatible with UID8451/10 wireless dimmer switch, SWS200 wireless scene switch, wireless Occ sensor (OCC SENSOR IA CM IP42 WH 10/1) and wireless Day/Occ sensor (OCC MULTI SENSOR IA CM WH 10/1) and wireless Occupancy or Daylight & Occupancy sensors available. Use Interact software and insights to increase building efficiency, achieve building wide integration and optimize space through occupancy analytics. SB option in addition to occupancy and daylight sensing supports advanced IoT capabilities such as people estimation analysis, desk level temperature & humidity sensing, noise classification, and BLE beacon. Requires compatible Gateway and internet connectivity for commissioning. For more information, visit: www.interacL-lighting.com/office or www,usa.lighcing.philips.com/systems/system- areas/offices_ Optional integral emergency controller and battery pack provides 6001m nominal output. Test switch and indicator light mounted on side of chassis on one end, Emergency battery has a 3 month pre -installed shelf life, and must be stored and installed in environments of 20C to 30C (-4F to 86F) ambient, and 45-85% relative humidity. For more information on Interact Office Wired, visit; www.interact-lighting_com/office or www,usa.lighting.philips.com/sysLems/system- areas/offices. Interact Office Wired (PoE), Static White: • A wireless IoT connected lighting solution for large enterprises that span across multiple floors, buildings and require multiple gateways. Emergency Options (ER100) (System Bridge Accessory with -ER100 option): Power Sensing (Factory default) - Recommended UL924 option requires unswitched power sense line, absence of voltage on the normal circuit triggers luminaire to 100% output Power Interruption Detection (Field option) - Detects AC power interruption >30ms triggers 90 minute emergency mode with luminaire at 100 % output Radio only sensor (RADIO): Integral RADIO only sensor simply enables wireless mesh connectivity to the luminaire without any occupancy or daylight sensing. Ideal for applications where sensing functionality is managed by other Interact devices and the luminaire only needs to have wireless connectivity. View all your projects under one dashboard and easily compare insights from multiple projects in one view. Compatible Zigbee Green Power wall dimmer and wireless Occupancy or Daylight & Occupancy sensors available. Use Interact Office software and insights to increase building efficiency, achieve building wide integration and optimize space through occupancy analytics. Supports advanced IoT Apps on wayfinding, room/desk reservation and offers open APIs Requires compatible Interact Office Gateway and internet connectivity for commissioning. For more information on Interact Office Wireless, visit: www.interact-lighting.com/ office or www.usa.lighting_plillips.com/systems/ system-areas/offices. LyteProfile-47in-PAR 12/21 page 3 of 6 Lyte?rofi!e-4in-P4R 12/21 page 4 of 6 PAR LyteProfile 4" Round Downlight & Lensed Wall Wash Dimensions tor" (276 mm) 71/" (221 mm) 24" (610 mm) MAX. Center point location for integral emergency Zest switch (IE146) 3'/4" t (83 mm) 4 /z" (114 mm) (60 mm) SaI -- -- (146 mm) A.irSeal (A) Emergency battery pack shown with EM6 option on new construction non -IC frame. (264 mm) ............. Round 4" 9'/" (235 mm) 14W _.... (365 mm) _ 11 %a" (292 mm) MAX. .,i New Construction 9 %11 (244 mm) installation -- - clearance required 43/a" (111 mm) I O 4 A. -- (124 mm) (13 mm) 4 Yx" /z.. Emergency battery pack (114 mm) (13 mm) shown with EM6 option on 5 Y., new construction non -IC frame. (146 mm) 131/4 i n 337 m m yin 7mm 163/etn _ Round 4" 416 mm AirSeal 111/4in 286 mm 6Main ° 1Lj156mm #°00e LyteProfi1e-4in-P4R 12/21 page 5 of 6 Electrical Product Input Volts Input Frequency Input Current (A) Input Power(W) P4*05*Z1CU/3 120 50/60Hz 0.06 7 277 0.029 7 P4*10*Z10U/3 120 50/60Hz 0.122 11 277 0.038 10 P4*15*Z10U/3 120 50/60Hz 0.13 15 277 0.063 16 P4*20*Z10U/3 120 50/60Hz 0.175 21 277 0.078 21 P4*25*Z10U/3 120 50/60Hz 0.22 26 277 0.099 27 P4*10*LU 120 50/60Hz 0.094 10 277 0.047 10 P4*15*LU 120 50/60Hz 0.134 15 277 0.07 15 P4*20*LU 120 50/6OHz 0.176 21 277 0.086 21 P4*25*LU 120 50/60Hz 0.23 27 277 0.106 28 P4R LyteProfile 4" Round Downlight & Lensed Wall Wash P4RDL20835CLZ10U * 20W LED, 80CRI, 3500K Candela Curves Angle Mean CP lumens Single unit data 0 937 Height to Initial center beam Beam 5 940 90 Lighted Plane foot-candles dia. (ft)* 10 956 15 960 271 5' 37 7. 0' 20 941 6' 26 8.4' 25 921 424 7' 19 9.8' 30 886 815 11.2' 35 836 520 9' 12 12,6' 40 759 45 652 495 * Beam diameter is where foot-candles 50 498 drop to50%of maximum. 55 289 250 60 65 54 20 24 Multiple unit data - RCR 2 70 75 12 6 7 Spacing Initial center beam Watts 80 3 on center foot-candles per sq.ft. 85 90 1 0 1 5' 90.3 0.87 6' 59.3 0.57 7' 423 041 Report': 155OGFR S. 35.3 0,34 9' 28.2 0,27,27 Output lumens: 20821ms Efficacy: 105.7lm/w 38'x38'x10' Room, Workplane 2.5' Spacing Criterion: 1.4 CCT3: 3500K above floor, 80/50/20%Reflectances Beam Angle: 99° CRI: 80min Input Watts': 19.7 W P4RLW20835CLZ10U * 20W LED, 80CRI, 3500K Candela Curve Multiple unit data Report': 1559GFR Footcandles on wall Efficacy: 104.6 Im/w 2' from wall Output lumens: 20601ms Input watts': 19.7 W 3' o� n ctr. CRI: 80 min 38 25 38 OCT 3: 3500K 1 o 2 64 51 64 3 59 54 59 rn 4 47 45 47 :o 5 36 36 36 0 6 28 28 28 E 0 7 23 23 23 8 19 19 19 9 16 16 16 ,tO.. 10 14 14 14 0 12 11 11 11 14 10 10 10 Coefficients of utilization Ceiling 80% I 70% 50% 1 30% 0% Wall 70 1 so l 30 l 10 150 110 50 1 10 50 101. 0 RCR Zonal cavity method - Effective floor reflectance =20% 0 119 119 119 119 116 116 111; 111 106 106 100 0 1 112 108 105 103 106 101 102 98 98 95 90 'W 2 104 98 93 88 96 87 93 85 90 84 80 3 97 88 82 77 87 76 84 75 82 74 71 y 4 90 80 73 67 79 67 76 66 74 65 62 A 5 83 72 65 59 71 59 69 58 68 58 55 v 6 77 66 58 53 65 52 63 52 62 52 49 o 7 72 60 53 47 59 47 58 47 57 46 44 0 8 67 55 48 42 55 42 53 42 52 42 40 9 63 51 43 38 50 38 49 38 48 38 36 10 59 47 40 35 46 35 46 35 45 35 33 Zonal lumens & percentages CRI and COT adjustment factors Zone Lumens %Luminaire 90CRI 2700K = 84% 0-30 785 37.7% 80CRI 2700K = 100% 0-40 1306 62.7% 80CRI 3000K = 100% 0-60 2050 98.5% 0-90 2082 100.0% 80CRI 3500K = 105% 80CRI4000K = 109% Multiple unit data Footcandles on wall 3�from wall 3' o0 n ctr. O 1 14 12 14 m 2 30 29 30 3 39 38 39 rn 4 40 39 40 L 5 :0 36 36 36 u 6 32 31 32 o 7 27 27 27 w 8 23 23 23 m 9 c 20 20 20 t0 10 17 17 17 0 12 14 14 14 14 12 12 12 Multiple unit data Footcandles on wall 3' from wall 4' oo n ctr.� 1 12 9 9 d 2 25 20 20 c 3 32 28 28 0 4 c 31 30 30 :5 5 28 27 27 0 6 24 24 24 o 7 21 21 21 8 18 18 18 m � 9 16 15 15 10 10 14 14 14 c, 12 11 11 11 14 10 10 10 1. Tested using absolute photometry as specified in LM79: IESNA Approved Method for the Electrical and Photometric Measurements of Solid -State Lighting Products. 2. Wattage: controlled to within 5% 3.Correlated Color Temperature: within specs as defined in ANSI-NEMA-ANSLG C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products.